Depending on your region the vent stack may protrude only a few inches above the surface of the roof.
Vent stack height above roof.
Above the roof plumbing vent height.
Vent pipes should extend to outdoors above the building roof and should terminate vertically not less than 6 above the roof surface nor more than 24 and must be at least 12 from any vertical surface such as a nearby sidewall.
In sizebefore penetrating a wall or roof and d where the buildingis 4 storeys or less in height the vent pipe terminates above the roof of the building.
C the vent pipe is increased to not less than 3 in.
And aavs on the branches.
Plumbing vent height above sloped roof i have a main vent and a sink vent and both are only 6 high above the roof.
This may seem suitable since the only purpose for the stack is to provide air and expel sewer gases.
The stack vent shall be permitted to connect with other stack vents and vent stacks in accordance with section 904 5.
This does not mean a few smaller vents 1 1 2 2 connecting and then increasing to 3 through the roof it means at least one soil or waste stack extending through the roof with a minimum diameter of 3.
The soil pipe also known as the vent stack or stack pipe provides air for the plumbing system.
Dubldare mn mn code requires at least one 3 vent stack carried full size through the roof.
Vent hight above roof cold climate.
The maximum height of drainage stack being vented by a maxi vent must not exceed six 6 branch intervals unless it is used in conjunction with a stack that is connected to a p a p a.
Upc i 906 1 and 906 2.
Offsets shall be permitted in the stack vent shall be located not less than 6 inches 152 mm above the flood level of the highest fixture and shall be in accordance with section 905 2.
Vents within 10 feet 3048 mm of a part of the roof that is used for assembly purposes or parking shall.
When a horizontal branch connects to a stack more than four 4 branch intervals from the top of the stack.
A relief vent shall be provided.
4 except for a fresh air inlet where a vent pipe is terminated in open air the terminal shall be located.
913 4 waste stack size.
Vent pipes shall be extended separately or combined of full required size not less than 6 inches 152 mm above the roof or fire wall.